Residual bond strength between steel bars and concrete after elevated temperatures, Fire Safety Journal, vol.44, pp.854-859, 2009. ,
Fastening Technique-Current Status and Future Trends, Symposium on Connections between Steel and Concrete, 55th RILEM Annual week, pp.1-17, 2001. ,
Behavior of Chemically Bonded Anchors, Journal of Structural Engineering, vol.119, issue.9, pp.2744-2762, 1993. ,
Force transfer in epoxy bonded steel/concrete joints, Int Adhes Adhes, vol.1, issue.2, pp.67-72, 1980. ,
Effect of heating rate on bond failure of rebars into concrete using polymer adhesives to simulate exposure to fire, Int Adhes Adhes, vol.31, issue.8, pp.851-861, 2011. ,
Study on dynamic pullout strength of anchors based on failure modes, 13th World Conference on Earthquake Engineering, vol.854, 2004. ,
,
Shear Strength of Adhesive Anchors, Precast Concrete Institute Journal, pp.92-100, 2002. ,
, Design Procedures for Concrete Anchors (Mechanical Expansion and Bonded Anchors), Michigan Transpostation Commission, 1998.
, Grout Bonded Concrete Anchors, 2011.
Résines époxydes (EP) -Composants et propriétés, Traité plastiques et composites, éditions T.I. (Techniques de l'ingénieur, 1992. ,
Creep behavior of cold curing epoxy adhesives: analysis and predictive approach, Composites In Civil Engineering (CICE), 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01207683
Numerical and experimental analysis of postinstalled rebars spliced with cast-in-place rebars, International Symposium on Connections between Steel and Concrete, vol.889, 2001. ,
Bond behaviour of the post-installed bundled rebars anchors with cement mortar in hardened concrete, Gheorghe asachi" din Iasi, vol.LXI, pp.117-129, 2015. ,
Parametric study of factors affecting the pull-out strength of steel rods bonded into precast concrete panels, Int Adhes Adhes, vol.21, issue.6, pp.489-493, 2001. ,
Estimation of ultimate tension load of methylmethacrylate bonded steel rods into concrete, Int Adhes Adhes, vol.27, issue.8, pp.653-660, 2007. ,
Performance under fire situations of concrete members reinforced with FRP rods: Bond models and design nomograms, Jornal of composites for construction, vol.16, issue.4, pp.395-406, 2012. ,
Dependence of Ultimate Bond Stress on Bond Anchor Carrying Capacity, Slovak Journal of Civil Engineering, pp.1-7, 2009. ,
Einfluss der Bohrlochereiningung und vo feuchtem Beton auf das Tragvehalten von ijektions düblen (Influence of hole cleaning and of humid concrete on the load bearing behaviour of injection anchors), 1998. ,
Bewehrungsnschlüsse mit nachträglich eingemöelten bewehrungstaben (Starter bars with post installed rebars), Beton und Stahlebetonbau, vol.97, issue.9, pp.445-459, 2002. ,
Recent Developments and Open Problems in Fastening Technique, 2nd International Symposium on Connections between Steel and Concrete, 2007. ,
Etude de la durabilité des assemblages collés, p.160, 2005. ,
Residual strength of organic anchorage adhesive for post-installed rebar at elevated temperatures and after heating, Fire Technology Journal, vol.52, pp.877-895, 2016. ,
Mechanical behavior changes of chemical anchors under high temperature exposure: Experimental investigation, International journal of adhesion and adhesives, vol.78, pp.200-211, 2017. ,
Effect of Temperature on the Mechanical Properties of Polymer Mortars, Materials Research, vol.15, issue.4, pp.645-649, 2012. ,
The effect of temperature on the strength of adhesive joints, International Journal of Adhesion and Adhesives, vol.12, issue.3, pp.185-190, 1992. ,
Prediction of failure of a cantilever-wall connection using post-installed rebars under thermal loading, Engineering structures, vol.56, pp.1607-1619, 2013. ,
, Comportement des Scellements Chimiques d'Armaturesraportées pour Béton en Situation d'Incendie, 2013.
Materials and fire threat, Fire technology journal, vol.33, issue.3, pp.260-275, 1997. ,
, EN 1992-1-1, Eurocode 2: Design of concrete structures -part 1-1: General rules and rules for buildings, 2004.
European Techniques of Anchor Guideline, 2001. ,
ACI 335.2-01, Evaluating the performance of post-installed mechanical anchors in concrete, 2001. ,
ASTM C881: Standard specification for epoxy-resin base bonding systems for concrete, 2013. ,
GB 50367-2006: Design code for strengthening concrete structure, 2006. ,
Expert report -Design of post-installed rebars with injection mortarFIS EM under fire exposure up to 240 min, 2008. ,
, EAD 330087-00-0601, Systems for post-installed rebar connections with mortar, 2015.
, EN 1992-1-2 Eurocode 2. Part 1-2: Design of concrete structures -General rulesStructural fire design, 2005.
Origin of the Invar effect in iron-nickel alloys, Nature, vol.400, pp.46-49, 1999. ,