The impact of microclimate conditions on energy demand is investigated through various coupling schemes between a zonal microclimatic tool and an urban building energy simulation software for a canyon settlement. Additionally, the impact of split air condition units on ambient air temperatures is examined for an annual period. The numerical calculations for a mild oceanic climate confirm the necessity of integrating the microclimate conditions in building energy performance simulations. Air conditioning units have a significant impact on air temperature both for cooling and heating period. Furthermore, discrepancies emerging from online and offline coupling schemes are highlighted.
Fichier principal
Vignette du fichier
Kyriakodis_UHIConf.pdf (977.35 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-02532686 , version 1 (05-04-2020)
hal-02532686 , version 2 (23-03-2021)

Identifiants

Citer

Georgios-Evrystheas Kyriakodis, Emmanuel Bozonnet, Peter Riederer. Minimizing the inconsistencies of urban building energy simulations through strong microclimate coupling. 5th International Conference on Countermeasures to Urban Heat Islands (IC2UHI2019), Dec 2019, Hyderabad, India. ⟨10.37285/bsp.ic2uhi.25⟩. ⟨hal-02532686v2⟩